AHF901 EPC Gas Chromatograph

 

Main features

► It can realize full EPC electronic flow control and full computer control of the gas chromatograph;

► High-precision gas flow ensures the accuracy and stability of GC analysis and daily analysis efficiency, and the EPC control accuracy is 0.01psi;

► Achieves self-protection against gas circuit failures, automatic ignition, and one-button start;

► Adopts advanced 10/100M adaptive Ethernet communication interface and built-in IP protocol stack to easily form a local area network to achieve long-distance transmission, remote control, and remote diagnosis;

► Equipped with IBrainChrom® workstation, which can support multiple chromatographs (253 units) working at the same time to achieve data processing and reverse control, reaching an industry-leading level;

The built-in Modbus/TCP server of IBrainChrom ® workstation can easily connect the analysis results to DCS (distributed control system).

 

         

Main technical parameters:

Model

AHF-901

Sample Introduction System

sample injector and evaporation chamber

Column Oven

Temperature range

RT ~ 450℃  (in 0.1 ℃ increment)

Temperature accuracy

± 0.01

Cooling time

260℃ to 50℃ in 6 min at 25℃ ambient

Programmed temperature

0.1℃~80℃/min (in 0.1℃ increment)

Program ramps

16 ramps in total

Flame Ionization Detector

(FID)

Detection limit

3x10-12g/s (C16)

Drift

1x10-13A/30min

Noise

3x10-14A

Linearity range

107

Thermal Conductivity Detector

(TCD)

Sensitivity

3000mV, mL/mg (C16)

Baseline noise

≤20µV

Drift

50µV/h

Linearity range

≥104

Flame Photometric Detector

(FPD)

Detection limit

(S)≤5×10-12g/s   (P)≤4×10-13g/s

Drift

2×10-12A/30min

Baseline noise

3×10-13A

Linearity range

(S)≥103(P)≥104

Electron Capture Detector (ECD)

Detection limit

2x10-12g/s

Drift

0.2mV/60min

Noise

0.02mV

Linearity range

 


No comment

Product Detail

AHF901 EPC Gas Chromatograph

 

Main features

► It can realize full EPC electronic flow control and full computer control of the gas chromatograph;

► High-precision gas flow ensures the accuracy and stability of GC analysis and daily analysis efficiency, and the EPC control accuracy is 0.01psi;

► Achieves self-protection against gas circuit failures, automatic ignition, and one-button start;

► Adopts advanced 10/100M adaptive Ethernet communication interface and built-in IP protocol stack to easily form a local area network to achieve long-distance transmission, remote control, and remote diagnosis;

► Equipped with IBrainChrom® workstation, which can support multiple chromatographs (253 units) working at the same time to achieve data processing and reverse control, reaching an industry-leading level;

The built-in Modbus/TCP server of IBrainChrom ® workstation can easily connect the analysis results to DCS (distributed control system).

 

         

Main technical parameters:

Model

AHF-901

Sample Introduction System

sample injector and evaporation chamber

Column Oven

Temperature range

RT ~ 450℃  (in 0.1 ℃ increment)

Temperature accuracy

± 0.01

Cooling time

260℃ to 50℃ in 6 min at 25℃ ambient

Programmed temperature

0.1℃~80℃/min (in 0.1℃ increment)

Program ramps

16 ramps in total

Flame Ionization Detector

(FID)

Detection limit

3x10-12g/s (C16)

Drift

1x10-13A/30min

Noise

3x10-14A

Linearity range

107

Thermal Conductivity Detector

(TCD)

Sensitivity

3000mV, mL/mg (C16)

Baseline noise

≤20µV

Drift

50µV/h

Linearity range

≥104

Flame Photometric Detector

(FPD)

Detection limit

(S)≤5×10-12g/s   (P)≤4×10-13g/s

Drift

2×10-12A/30min

Baseline noise

3×10-13A

Linearity range

(S)≥103(P)≥104

Electron Capture Detector (ECD)

Detection limit

2x10-12g/s

Drift

0.2mV/60min

Noise

0.02mV

Linearity range

 


AY-GC-901 Gas Chromatograph
Long press to look detail
Long by picture save/share
INQUIRY

在线询盘 MORE+
  • Contact person *

  • e-mail *

  • Your needs *

  • Submit

  • Security Code
    Refresh the code
    Cancel
    Confirm

Inquiry Content:


You have no items to require

Add Successfully

AY-GC-901 Gas Chromatograph

Enquiry
INQUIRY

在线询盘 MORE+
  • Contact person *

  • e-mail *

  • Your needs *

  • Submit

  • Security Code
    Refresh the code
    Cancel
    Confirm

Inquiry Content:


You have no items to require

Add Successfully

ADDRESS

 

No. 609, High Tech Houju Street, Qingshanhu District, Nanchang City, Jiangxi Province

           


     David                Mabel               James                Elly

CONTACT

 

Ph:   +86 18079100967

          +86 19318537228 

          +86 18170839926

          +86 19318553935

           

         

                                   

     

Mail:  mabel@jx-aiyi.com 

            anli@jx-aiyi.com

            david@jx-aiyi.com

            james@jx-aiyi.com

         

         

           

         
           

NEWSLETTER

  • E-mail

  • Submit

  • Security Code
    Refresh the code
    Cancel
    Confirm

Copyright © 2024  All Rights Reserved.

ABOUT         CONTACT         PRODUCT

Add WeChat friend to learn more about the product
Use Enterprise WeChat
"Scan" to join the group chat
Copy success!
Add WeChat friend to learn more about the product
I see.