Industry application scheme
Industry Application Scheme
Product composition:
1. High pressure infusion pump LC500Q * 2 sets
2. Uv detector SPD-500
PDAD Diode Array detector (optional)
RI-2000 Differential Detector (optional)
3. High pressure MIXER Mixer-500
4. The column is prepared by itself
5 Starting the Tool Package (Gradient)
6. Chromatographic control software WK-500
7.3725i Manual Sampling Valve (with support and metering ring)
8. Automatic fraction collector
This configuration scheme is a relatively complete high performance liquid chromatography (HPLC) system, which can be widely used in drug analysis, environmental monitoring, food safety, natural product analysis and other fields. Effective separation and detection of different types of compounds can be achieved by selecting suitable columns and detectors. At the same time, the system has a high degree of automation and intelligence, which helps to improve the analysis efficiency and accuracy. Below is a brief overview of the individual components and their possible areas of application
HPLC PUMP
High pressure infusion pump LC500Q * 2 sets:

High pressure infusion pump is one of the core components of HPLC system, which is responsible for transporting mobile phase (solvent) to the column in a stable and high pressure manner.
The configuration of the two pumps may be used for gradient elution, that is, changing the composition of the mobile phase over different time periods to achieve effective separation of different components in a complex sample.
Suitable for a variety of analytical tasks, such as drug analysis, environmental monitoring, food safety, etc.
UV Detector :
An ultraviolet detector detects the components of a sample by measuring its absorption under ultraviolet light.
It is suitable for compounds containing UV-absorbing groups, such as most organic compounds, drugs, dyes, etc.
PDAD Diode Array detector (optional) :

The PDAD detector can detect samples at multiple wavelengths at the same time, providing rich spectral information.
It is suitable for tasks that require simultaneous detection of multiple components or spectral analysis, such as drug impurity analysis, natural product analysis, etc.
HPLC With RI Detector
RI-2000 differential detector (optional) :

A difference detector detects the composition of a sample by measuring the difference in refractive index between it and the mobile phase.
It is suitable for compounds that do not contain ultraviolet absorption groups or fluorescence properties, such as sugars, polymers, etc.
High pressure mixer

High pressure mixers are used to mix different proportions of mobile phases to form the required gradient elution conditions.
It is an indispensable component in gradient elution HPLC system.
Launch kit (gradient) :
Startup kits may contain tools and accessories needed to install, commission, and start up HPLC systems.
Helps ensure proper installation and stable operation of the system.
Chromatographic control software WK-500:
Chromatographic control software is used to control the operation of HPLC systems, including setting instrument parameters, collecting and analyzing data, etc.
It provides a user-friendly interface and powerful data processing functions to help improve work efficiency and accuracy.
3725i Manual sampling valve (with valve bracket and measuring ring) :

Manual sample injection valves are used to inject samples into HPLC systems.
The quantification ring is used to ensure that the sample size is consistent for each injection, thus improving the accuracy of the analysis.
Automatic fraction collector:

An automatic distillate collector is used to collect individual components after HPLC separation.
Suitable for tasks requiring the collection and analysis of multiple components or large-scale sample analysis.